General Safety Precautions; Product Description; Technical Characteristics Of The Magnetic Sensor; Installation - Roger Technology ACS/BA/60 Instrucciones Y Advertencias Para El Instalador

Ocultar thumbs Ver también para ACS/BA/60:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 26
1

General safety precautions

Warning: incorrect installation may
cause severe damage or injury.
Read the instructions carefully before
installing the product.
This installation manual is intended for qualified
personnel only. ROGER TECHNOLOGY cannot be
held responsible for any damage or injury due to
improper use or any use other the intended usage
indicated in this manual.

Installation,

electrical
adjustments must be performed by qualified
personnel, in accordance with best practices and
in compliance with applicable regulations. Before
installing the product, make sure it is in perfect
condition.
Disconnect the mains electrical power before
performing any work. Only use original spare parts
when repairing or replacing products.
The packaging materials (plastic, polystyrene,
etc.) should not be discarded in the environment or
left within reach of children, as they are a potential
source of danger.
WARNING!
Handle
terminals with extreme care, as these parts are
highly sensitive to static electricity.
2

Product description

The boom connection ACS/BA/60 - ACS/BA/68 is a
safety device for disengaging the booms of the BIONIK
barriers.
Following an impact to the boom, the system disengages,
protecting the boom and the barrier against serious
damage. The built-in sensor interrupts the operation of
the automation system.
The connection of the detachable boom ACS/BA/60 -
ACS/BA/68 can be used with the firmware version r3.50
(or later) of the control unit CTRL or with the firmware
version c1.30 (o later) of the control unit CTRL/P.
3
Technical characteristics of
the magnetic sensor
TECHNOLOGY USED
MAINS POWER VOLTAGE
CURRENT ABSORPTION
OUTPUT TYPE
MAXIMUM VOLTAGE
APPLICABLE AT THE OUTPUT
OPERATING TEMPERATURE
connections
and
electronic
parts
and
Unipolar, HALL
effect sensor
24Vdc ±15%
8mA
Open Collector
12Vdc
-20°C
+55°C
4
Installation
The ACS/BA/60 system uses the BA/60/3 round boom,
up to 3 meters in length.
The ACS/BA/68 system uses the BA/60/3 elliptical
boom, up to 3 meters in length, BA/60/4 elliptical boom,
up to 4meters in length.
To install the ACS/BA/60, see pag 3 for BI/004 or pag 4
for BI/001PC - BI/001PE - BI/004HP.
To install the ACS/BA/68, see pag 5-6 for BI/004 or pag
7-8 for BI/001PC - BI/001PE - BI/004HP.
4.1

BI/004 installation with ACS/BA/60

(pag. 5)
1. Pass the connecting cable through the crankshaft
and make it come out from the opposite side.
2. Partially tighten the 12 screws [B] M10x16 as shown
in detail 1.
3. Insert the rod holder [A] into the motor shaft.
4. Tighten the 12 screws [B] M10x16 until fully secured.
5. Insert the boom [C] BA/60/3 in the cylindrical bracket
[E] and fasten it with the 4 self-tapping screws [F].
NOTE: Before inserting the boom into the bracket,
apply the supplied adhesive tape [D].
6. Insert the rod fully inside the rod support [A] and
fasten it with the screw [G] M12x100.
7. Put the cover [H] and fasten it with the 2 screws
supplied.
8. Pass the connecting cable through the centre of the
linkage lever [detail I].
9. Fasten the cable with the cable clamp located inside
the barrier supporting structure [detail L]
10. Feed the cable into the control unit [detail M],
ensuring that the cable does not interfere with the
movements of the automation system.
11. Continue with the electrical connections.
4.2
BI/001PC-BI/001PE-BI/004HP
installation with ACS/BA/60 (pag. 6)
1. Remove the flange [A] from the crankshaft.
NOTE: This product must be disposed of only
by
qualified
technical
suitable procedures. Observe local legislation for
differentiated refuse collection.
2. Pass the connecting cable through the crankshaft
and make it come out from the opposite side.
3. Fasten the [B] boom support to the crankshaft with
the 4 [C] M12x80 screws.
4. Insert the boom [D] BA/60/3 in the cylindrical bracket
[F] and fasten it with the 4 self-tapping screws [G].
NOTE: Before inserting the boom into the bracket,
apply the supplied adhesive tape [E].
5. Insert the rod fully inside the rod support [B] and
fasten it with the screw [H] M12x100.
6. Put the cover [I] and fasten it with the 2 screws
personnel,
following
17

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Acs/ba/68

Tabla de contenido