Key And Symbols For Consultation; Use Conditions; Intended Use; Limitations Of Use - Roger Technology AGILIK Instrucciones Y Advertencias Para El Instalador

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 59
INTRODUCTION TO THE INSTALLATION MANUAL
WARNING! PLEASE READ CAREFULLY
This installation manual contains important warnings and safety instructions
for installation. Incorrect installation or incorrect use of the product can
cause severe damage to both property and people.
Please keep this installation manual for future reference.
1

KEY AND SYMBOLS FOR CONSULTATION

This installation manual is intended solely and exclusively for the technical
staff that is professionally qualified and competent to perform the installation
task.
This installation and maintenance manual is an integral part of the installed
product and must be delivered to the end user for safe storage.
SYMBOLS USED:
! This refers to information that we strongly recommend you read,
for your personal safety, for the safety of others and to avoid
damage to property.
#
This refers to warnings on recycling.
Refers to the voltage grounding
2

USE CONDITIONS

2.1) Intended use

The Agilik automatic barrier has been conceived, designed and produced to
be installed for use in private or public car parks, residential, commercial and
industrial areas or in areas with a high intensity of passage.
Therefore, this product must and will only be used for the purpose for which
it has been designed. Any other use other than that mentioned is prohibited.
The manufacturer cannot be held either directly or indirectly responsible for
any damage caused by incorrect, improper or unreasonable use.

2.2) Limitations of use

The Agilik series road barrier has been designed for very intensive work
cycles; can be installed with a bar length of up to 6 metres, with opening
cycles from 2-6 seconds for the version with a bar length of up to 4 metre
and 4-8 seconds for the version with the bar length up to 6 metres.
3

GENERAL WARNINGS FOR INSTALLATION AND MAINTENANCE

Carefully read all the information contained in this installation manual, as
they contain important information regarding installation, safe use and the
related maintenance. Any installation or use other than what is shown in the
following installation manual is prohibited.
Warning: The installation, electrical connection, adjustment and maintenance
of the automation installed must be carried out by professionally qualified
technical personnel. Incorrect installation or incorrect use of the product will
cause serious damage to people or property.
RISK ANALYSIS:
! Warning: the installer must analyse the hazards that may occur in the
automated closing or the closing to be automated and for each hazard must
adopt solutions to permanently remove it.
PRELIMINARY OPERATIONS:
Before connecting the equipment, ensure that the data on the plate
correspond to those of the electricity distribution network and that the
model conforms to the dimensions and weight of the door.
! Warning: this equipment can exert very high forces that can be a source
of hazard.
! Warning: Before performing the installation, carefully check the strength
and stiffness of the gate, the pillar, the guides, the mechanical stops in
opening and closing, and that manual operation is smooth and regular.
CONNECTING TO THE MAINS
! Warning: Before connecting to the mains, check and perform the
following steps:
1) Always provide an upstream differential switch with a threshold of 0.03 A.
2) Provide a suitable double pole switch with a contact gap of at least 3 mm,
provided with protection against overloads and short circuits dedicated only
to automation.
3) It is mandatory to connect the yellow-green conductor to the terminal
marked with the symbol
! Warning: The safety of this equipment is guaranteed only when it is
correctly connected to an efficient grounding system, made according to
current safety standards.
! It is necessary to verify this fundamental safety requirement; If in doubt,
check the grounding system.
!
Warning: connect the metal closing structure to the ground. The
manufacturer cannot be held responsible for any damage caused by the
system lacking grounding.
! Warning: Do not operate in wet or damp environments without
appropriate protection against electric shocks.
! Warning: Before performing any adjustments, maintenance or cleaning,
always cut off the power supply.
! Warning: Do not install the device in an explosive environment; the
presence of flammable gases or fumes is a serious safety hazard.
! Warning: For maintenance, only use original Roger Technology spare
parts.
! Warning: automation must not be put into operation before definitively
making all connections, testing the efficiency of the safety devices and
setting the thrust force at a minimum.
FINAL CHECKS:
Check the correct operation of the safety devices and the stroke end
microswitches; check that the thrust force is within the limits of the
standards in force and that the good mechanical safety stops are correctly
sealed during opening and closing.
MARKING PLATE:
Clearly indicate in the vicinity of the passage that the equipment is automatic
and controlled remotely.
PACKING:
! Open the package by orienting the package with the arrows as indicated
on the packing. After removing the packing, make sure of the integrity of the
equipment. If in doubt, do not use the equipment and contact a qualified
technician.
! Warning: the packaging components (plastic bags, polystyrene foam,
nails, cardboard boxes, etc.) must not be left within reach of children as they
are potential sources of danger.
#
Dispose of and recycle the packing components in accordance with the
standards in force.
#
There are no particular risks arising from the automation itself; if possible,
recycle the various components separately (aluminium, iron, electrical parts,
etc.).
! Warning: the installer must provide the end user with all instructions
and warnings of the operation of the automated system and, in particular,
the operation of the manual opening operation in the event of emergency.
! Warning: the installer must provide a series of special warnings for the
user (see user guide) and, if possible, display them in a convenient place.
17

Publicidad

Tabla de contenido
loading

Tabla de contenido