Important! The fitting must be installed, flushed and
tested after the valid norms!
The mixer can not used together with a continuous flow
water heater.
Assembly
1. Flush through the supply pipes.
2. Place the mixer including the sealing washer in posi-
tion on the basin.
3. Slide the fixation piece including the washer over
the threaded pins and tighten the nuts.
4. Connect the supply pipes to the isolation valves;
5. cold right - hot left.
6. Connect the Isiflex hose with the handshower and
the mixer.
The hot and cold supplies must be of equal pressures.
Operation
The handshower is activated by pressing the button, the
spout of the mixer is closed. After the button is released,
the handshower is closed und the spout of the mixer is
activated.
Operation
open
English
close
Technical Data
Operating pressure:
Recommended operating pressure: 0,25 – 0,5 MPa
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Rate of flow mixer:
Rate of flow handshower:
Spare parts (see page 3)
1
flange
2
handle
3
nut
4
cartridge cpl.
5
aerator
6
supply pipe
7
Isiflex shower hose
8
hand shower
9
chain for plug
10
shower holder
11
fixing set
12
handle
13
flange
14
aerator
15
flange
16
shower holder
cold
max. 1 MPa
1,6 MPa
max. 80°C
65°C
6,5 l/min 0,3 MPa
8,5 l/min 0,3 MPa
97155000
10092000
97157000
96339000
97691000
96638000
28246000
96907000
97109000
28331000
97774000
39091000
96671000
13085000
95396000
39525000
hot