12. Use the switch on the back to set the temperature measurement unit (default
setting:
o
C).
13. A flashing LED icon on the display indicates that a signal is being transmitted.
The icon will flash every 50 seconds for channel 1, every 53 for channel 2 and
every 56 for channel 3.
14. Activate the other two sensors in the same manner.
Be sure to set a different channel on each sensor.
3.3.2.
Calibration
1. In standard mode press "CHANNEL" button. "CH1" will appear on the display.
2. Press the "CHANNEL" button until the display shows the message
corresponding to the desired channel (order of messages displayed:
"CH1" -> "CH2" -> "CH3" -> "IN" -> "CH1"). The display will start flashing the
selected message at a frequency of 1 Hz.
3. Temperature calibration:
a) After entering the calibration menu, press the "TIME SET/12/24" and "UP"
buttons.
b) With the buttons "UP/MAX/MIN" (+) and "DOWN/C/F" (-) to set the current
measurement value.
A single press of each of these buttons will change the parameter value by
0.1
To significantly increase or decrease the value, e.g. by several degrees,
o
press and hold a button (the value will change by 8
c)
To confirm, press the "TIME SET/12/24" button.
4. Humidity calibration:
a) After entering the calibration menu, press the "TIME SET/12/24" and
"DOWN/C/F" buttons.
per second).
o