Tool Storing And Battery Maintenance; Anvil Replacement; Special Maintenance; Periodic Maintenance Schedule - CAMPAGNOLA Cobra Manual De Uso Y Mantenimiento

Tijera electrónica
Ocultar thumbs Ver también para Cobra:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 20
6 - MAINTENANCE

6.1.6 Tool storing and battery maintenance

Before storing the tool for a period of time it is necessary to:
• Perform a complete battery set (1) re-charge cycle.
• Every 120 days effect a complete battery set (1) re-charge cycle.
• During the storing period, do not leave the shear in the rain and keep it a dry place in its box.
WARNING!
• If the battery set (1) is not re-charged every 120 days, as duly indicated in par. 7.1.6, it will
irreparably get damaged.

6.1.7 Anvil replacement

The following operations shall be performed in the indicated order:
• Remove the cutting blade (14) (see par. 6.1.4)
• Remove the screws (25)
• Replace the anvil (16)
• Assemble the pin (29) in the anvil (16) and in the shear body
• Align the anvil fixing holes with the body threads
• Tighten the nut (22) on the pin (29)
• Tighten the screws (25) adding Loctite 270 or something equivalent
• Remove the nut (22) and the pin (29)
• Assemble the cutting blade (14) (see par. 6.1.4)

6.2 Special maintenance

WARNING!
Any special maintenance operation shall only be carried out by a CAMPAGNOLA S.r.l. Authorized Service
Point.

6.3 Periodic maintenance schedule

Maintenance
Cutting blade (14)
sharpening
Cutting blade (14)
replacement
Thorough overhaul by a
Campagnola Service Point
Blades (15) and pin (29)
lubrication
Battery set (1)
maintenance re-charge

7 - DISMANTLING AND DISPOSING OF THE COMPONENTS

7.1 General

At the end of its working life, the tool has to be dismantled.
The tool components shall be divided in order to dispose of them according to the materials they are made of
(batteries, metal, plastic, etc) and in compliance with the regulations of the country where the tool was used.

7.2 Dead batteries disposal

The dead and/or damaged batteries disposal and handling have to be carried out according to the Directive
91/157/CE or the corresponding regulations of the country where the batteries were used.
46 - 112
After the first
Every
½ work hour
day
X
X
X
Every 200.000 cuts (about
100 hours)
X
Every
At the end
400.000
of each
cuts (100
work
hours more
season
or less)
X
X
X
Every 120
days
X

Publicidad