5 – USE OF THE TOOL
ATTENTION!
Please note that the battery charge value is approximate. We suggest you should recharge the battery at
the end of each working day.
3) Status: NORMAL indicates that the tool works well; STANDBY indicates that the trigger protection
is on (after 1 minute without working); RESTART indicates that the tool is in safety block (after 5
minutes without working); flashing STOP followed by OVERLOAD indicates that the shear cannot
operate due to inner overheating; flashing STOP followed by MAX_TEMP indicates shear
overheating (more information can be found in par. 5.4); flashing SERVICE indicates that it has
been reached the number of cuts for the check at a CAMPAGNOLA Authorized Service Point (it
is possible to go on working, but the check procedures have to be carried out as soon as
possible).
WARNING!
The disregard of the necessary checks at an Authorised Service Point will make any warranty claims
become void.
4) Motor temperature
1
2
- For the Service mode:
1) Service mode
2) Blade tightening status
3) Number of cuts carried out by the tool
4) PASS/NO PASS test results (for more information see par. 6.1.3)

5.2 Shear stopping

The shear shall always be kept in its holster (32) with closed blades (15):
Keeping the trigger (12) pressed, close the cutting blade (14), then turn the selector to switch the tool off and
disconnect the battery by means of the switch (8).
WARNING!
Do not over-press the trigger (12), since it would not increase the cutting power.

5.3 Battery re-charging

For the recharge operations and the battery-charger functioning please read its own manual

5.4 TROUBLESHOOTING

WARNING!
All extraordinary maintenance operations shall be carried out only by a service mechanic.
FAULTS
The shear does not work.
CAUSE
Flat battery (1).
Switched-off battery (1)
Selector (19) in OFF position
Disconnected electronic unit
3
4
REMEDY
Re-charge the battery (1).
Put the switch (8) in position I
Turn the selector anti-clockwise
Check the connection between the
43 - 112