10. Install the AC Multi-Output Supply
AC Gang
Supply
Mount the AC supply under the deck using the two screws provided. Orient as
shown.
Remove the cover.
Connect the faucet wire to the faucet. Maintain a drip loop when connecting.
If needed, cut and strip the AC supply wires to length.
Connect the stripped ends to the bottom terminal block in the supply box.
Secure the terminal box cover to the terminal box.
NOTE: If a hard wired installation is required, refer to "Hard Wire Installation".
Plug the AC supply into an unswitched 120 VAC electrical outlet.
Secure any excess wire under the deck.
IMPORTANT! The area in front of the sensor must be free of objects during the 2
minute learning cycle or the faucet may not function properly.
Allow 2 minutes for the sensor to cycle through the automatic sensing distance.