Troubleshooting Guide - Agio 2127022 Manual Del Usuario

5 piezas juego de sala tejida con chimenea
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PROBLEM
Burner Won't Light
Burner won't stay
lit after lighting

TROUBLESHOOTING GUIDE

CAUSE
No propane gas at the
burner
No spark at the electrode
Lack of oxygen
Thermocouple not in flame
Thermocouple connection
at the main control valve is
loose
No fire ice on the burner
REMEDY
Check that the gas tank valve is open.
Turn the control knob to "ON" and push
the control knob in. Make sure the tank
has propane gas.
Check that the AA battery is installed
with the negative (-) end first and has a
charge. Check that the wire is
connected to the ignition module.
Check that the electrode is not cracked
or broken.
Remove excess fire ice from around
the ignition well.
Check that the tip of the thermocouple
is even with the top of the ignition well.
Remove any fire ice from the ignition
well.
Tighten the thermocouple nut at the
back of the valve.
Cover the burner with fire ice per the
instructions.
11

Publicidad

Tabla de contenido
loading

Tabla de contenido