Stopping the Engine
1. Turn off and remove entire electrical loads.
Never start or stop the generator with electrical
devices plugged in or turned on.
Let the generator run at no-load for two minutes to
stabilize internal temperatures of the engine and
generator.
2a. Electric start operation
Push and hold the START/STOP button for
one second.
2b. Remote start operation
Push STOP on the remote start key fob for one
second.
2c. Recoil Start operation
Turn the engine switch to the "OFF(O)"
3. Turn the fuel switch to the "OFF"
4. Turn the fuel valve knob to the OFF
WARNING
Fuel and its vapors are extremely flammable and
explosive which could cause burns, fire or explosion
resulting in death or serious injury.
NOTE:
If the engine will not be used for a period of two
weeks or longer, please see the Storage section for
proper engine and fuel storage.
Low Oil Shutdown
If the engine oil drops below a preset level, an oil
switch will stop the engine. Check oil level with
dipstick.
If oil level is between LOW and HIGH mark on
dipstick:
1. DO NOT try to restart the engine.
2. Contact an Authorized Service Dealer.
position.
3. DO NOT operate engine until oil level is corrected.
If oil level is below LOW mark on dipstick:
1. Add oil to bring level to HIGH mark.
2. Restart engine and if the engine stops again a low
oil condition may still exist. DO NOT try to restart
the engine.
3. Contact Customer Service.
4. DO NOT operate engine until oil level is corrected.
Page 22
position.
position