Parameter
30 btlt
ESC
MODE
31 HHbO
ESC
MODE
32 CHdE
ESC
MODE
00 EHIt
Description
Enabling/disabling backlighting.
Value can be set to ON/OFF.
By setting the value to ON, back-
lighting is enabled.
From the HOME screen, turn the
backlighting on using the UP
and DOWN
buttons.
Backlighting times out 5 seconds
after the last button was pressed.
By setting the value to OFF, back-
lighting is disabled, i.e. it is not
turned on with each intervention,
prolonging battery life. Press the
SET/PROG or ESC/MODE button to re-
turn to the home screen.
Maximun boilerl central heating tem-
perature setpoint (available with
OTBus connection between the
WiFi Box and the boiler or the
RF receiver and the boiler or the
Hi, Comfort T100 and the boiler, if
provided for by the OTBus protocol).
The value can be set between 80°C
and 40°C (for high temperature heat-
ing) or from 45°C to 20°C (for low tem-
perature heating).
This parameter has to be set by the
Authorised Service Centre.
A delay on heating requests is applied on
the RF channel only in the direction of the
Wifi box and the boiler receiver, and can be
used on systems with zone valves without
the limit switch to delay start-up of the
boiler until the valves are completely open.
The heating request, activated by the timer
thermostat with local relay remains instant.
If the parameter is set at 0 the delay is not
active; if set to another value the delay de-
pends on the value set in the parameter.
The parameter can be set from 0 to 255 sec.
in intervals of 5 sec. and the default value
is 0.
Press the SET/PROG button or ESC/
MODE to return to the HOME screen.
116