3.13
RF receiver configuration
The RF receiver can be configured to be
used as a boiler RF receiver or as an RF
receiver for the zone valve.
The receiver is factory set as the boiler
RF receiver.
To configure the RF receiver proceed as
follows:
− Power up the receiver
− Press button B once during the
two seconds in which the green
and red leds remain lit.
The operating mode of the RF receiver
switches from boiler RF receiver to zone
valve RF receiver and vice versa.
Boiler RF
receiver
The change in configuration is identifi-
able by the different flashing mode of
the green led.
Configured as boiler RF receiver
Green LED
0.5 sec. on
Relay Off
0.5 sec. off
0.2 sec. on
Relay On
0.2 sec. off
Relay Off
Relay On
NOTE
If the receiver is configured as a boiler
RF receiver, the Opentherm connection
to the boiler should be detached to en-
able display of the flashing green led.
3.14 Linking function
Hi, Comfort T100 linking with the WiFi
Box
The Hi, Comfort T100 and the WiFi Box
in the WiFi Hi, Comfort T100 pack-
age are already linked.If installing an
additional Hi, Comfort T100, follow
the procedure below. Ensure that the
Hi, Comfort T100 and the WiFi Box are
connected to a power source and there
are no alarms. Press the prismatic dome
clear LED button (A) and hold for 5 sec-
onds until the green and red LEDs slow
B
flashing (1 seconds) at the same time
(once linked the flash will return to
normal).
Red LED
-
-
From the Hi, Comfort T100 HOME
screen, press the ESC/MODE button
and hold for 5 seconds to display the
following (alternating) information.
117
Configured as zone receiver
Green LED
2 sec. on
2 sec. off
1 sec. on
1 sec. off
WiFi Box
Red LED
-
-
A