Riello Hi, Comfort 100 Manual Instalador Y Usuario página 125

Ocultar thumbs Ver también para Hi, Comfort 100:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 188
Alarm
SET
PROG
RESET
Batteries running low
Alarm
A01-A10
Burner ignition/detection failure after numerous attempts
A02-A20
Limit thermostat tripped
Flue gas thermostat and/or safety thermostat and/or air pressure
A03-A30
switch and/or fan fault
A04-A40
Primary circuit pressure insufficient
A06-A60
DHW NTC probe anomaly
Alarm relating to heating NTC probe and/or delivery NTC probe and/
A07-A70
or excessive differential between the delivery and return NTC probes
NTC return probe alarm and/or excessive differential between the
A08-A80
combustion probes
NTC smoke probe alarm or exchanger dirty and combustion non
A09-A90
coherent
A77
Low external temperature limit thermostat tripped
A99
Too many resets performed via remote control
The alarm history can be viewed under the parameter ALL from the advanced pro-
gramming menu.
For details of boiler alarms, please see the boiler installer manual.
Description
125
Solution
To replace the batteries, remove
the Hi, Comfort T100 from its
base.
− Replace the batteries.
− Check that the contacts
are not rusty.
− Replace
Hi, Comfort T100.
− Contact the Authorised
Service Centre.
9
Replace the batteries as
soon as possible. When
ESC
the low battery warning
MODE
is on, correct operation of
the Hi, Comfort T100 and
any RF communication is
no longer guaranteed.
Description
the

Publicidad

Tabla de contenido
loading

Tabla de contenido