Do not over-mix fuel, to store it for the future. Stored fuel/oil mixture for two-stroke
engines may separate and become unusable, causing damage to the device's engine.
Do not prepare the mixture directly in the device's tank!
Observe the following rules when refueling:
- Never add fuel when the engine is hot.
- Use only fresh, uncontaminated petrol.
- Never add fuel when the engine is running.
- Do not fuel the tank indoors.

REFILLING THE TANK

1. When refilling with liquid agents, move the metering tap to the closed
position.
2. When refilling with powder agents, set the metering lever and the throttle
lever to the lower positions (0).
3. Unscrew the hopper cover. Using extreme caution, place the chemical inside
the tank. Carefully, tighten the cover.
Caution: Do not refill the tank when the device is working! It can be done only
when the device is switched off.
3.3.
3.3.1. Starting
Caution: Before starting the device, check:
- The level of fuel in the tank;
- If the spark plug cap is tight (a loose cap can cause sparks and ignite fuel
vapors).
- Make sure that the chemical discharge valves are set to the closed
position.
1. Refill the tank with a spray agent.
2. When starting with a cold engine, turn off the suction by moving the
suction lever to the half-open position (diagonal).
When starting a warm engine, move the suction lever to the open
position (horizontal).
3. Set the tank valve to the open position.

Working with the device