Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
28/29
Once the adjustment has been made, refit the protective cover. The temperature controller (Pro-
portional Integral Derivative) ensures that the output hot air temperature is maintained constant.
The heated hose prevents heat loss of the air.

06. Warnings

Before putting into operation and especially after each cleaning and/or repair process, check
that the components of the equipment are perfectly tight and that the hoses are sealed (without
leaks). You must replace or properly repair defective parts.
IT IS ESSENTIAL to have a differential switch enabled for the power
supply line of the PACK 6000X. Otherwise, have at least one 2-pole
circuit breaker (1P + N) installed.
It is recommended outside working hours to completely disconnect the power supply from the
PACK 6000X by directly removing the plug from the plug or turning off the 2-pole circuit breaker
(1P + N) on the main electrical panel.
The PACK 6000X AIR HEATER equipment is manufactured to achieve safety in use.
Nevertheless during the use of the equipment hazards for the operator or incidents
may occur in the installation if the equipment is used by operators that are not properly
trained or instructed or it is not used in accordance with the recommendations.
Use it according to the usage, maintenance and safety instructions in this manual and do the
practice applications required to achieve the desired finish quality.
The equipment is supplied depressurised (without pressure inside).
Use ANTI-STATIC AIR HOSES.
Connect the equipment to a GROUNDED POWER SUPPLY.
The total shunt resistance of the line must be <1 million ohms.
Carefully read and apply all the information, instructions and safety measures indicated by the
manufacturer of the products to be used (products to be applied, solvents, etc.), as these may
cause chemical reactions, fires and/or explosions or be toxic, irritant or noxious and in any event
hazardous for the health and integrity of the user and people around him (See section on Health
and Safety).
The typical expected working regime is of up to 70
and must be corrected according to the distance between the equipment and the spray gun or
application tool (hot air consumption point) to compensate for heat losses in this stretch.
Switch off the heater after use to reduce electricity consumption and prevent accelerated dete-
rioration of the heated hose.
EQUIPMENT DESIGNED TO BE OPERATED IN WELL VENTILATED ENVIRON-
MENTS. KEEP WELL AWAY FROM ANY POTENTIALLY EXPLOSIVE ATMOS-
PHERE.
o
C. This working regime is merely a guideline
ENGLISH

Publicidad

Tabla de contenido
loading

Tabla de contenido