NOTE!
•
The pipe must always be installed vertically above the
roof and extend at least 600 mm above the roof surface.
If the outlet air pipe is to be enclosed (e.g. using metal
siding), make sure that the end of the pipe extends at
least 400 mm above the enclosure.
•
If installing where snow is likely to accumulate, it may
be necessary to extend the pipe further, and to secure
accordingly. Keep in mind not to extend beyond the
maximum allowed pipe length.
NOTE!
Cinderella supplies a specially designed "siphon" that fits
onto the elbow provided in the installation kit. This item can
be purchased as an accessory from any Cinderella dealer.
If installation is done from inside, you will need to connect
the siphon to the elbow piece to prevent condensation and
rainwater from draining onto the floor. Failure to collect the
condensation and empty it regularly may result in damage
to the floor.
2.5.2 INLET AIR TERMINAL
An inlet air vent in accordance with manufacturer specifications is required to ensure adequate air circulation
and the oxygen required for proper incineration. The Cinderella Original Installation Kit includes a specially
designed air vent designed for optimal flow and increased product efficiency. The air inlet vent should preferably
be installed as close to the Cinderella toilet as possible, to ensure a good air supply to the toilet and reduce the
environmental impact in the toilet room. It is important that there are no other air-dependent installations used
at the same time as the toilet, e.g. an extractor fan or fireplace. The Cinderella Freedom toilet draws air mainly
from the underside of the toilet. It is therefore possible to have the air intake underneath the toilet. This allows
you to insulate the air as much as possible in the toilet and minimise the environmental impact in the toilet
room.
NOTE!
•
•
•
•
•
10
The inlet vent's minimum dimensions must be 160 mm (diameter)/201 cm².
The vent must be open at all times when using the appliance. Remember to clean the
vent at regular intervals.
Make sure that there is no conflict between the toilet's air supply and other
installations, such as a fireplace or extractor fan.
Do not use a separate ventilation fan or similar to extract air from the room where the
toilet is installed when using the Cinderella Freedom toilet.
If you have open ventilation under the toilet, it may be advisable to use a mesh over the
hole to prevent insects and vermin from entering the toilet. Make sure that the mesh is
not too fine – a minimum of 5 mm – as smaller mesh will impede the air flow.
NOTE!
If the installed air vent has an adjustable opening, always
make sure to leave it open by a minimum of 75 mm (two
clicks) when operating the toilet.