2.5.3 INSTALLING THE ORIGINAL CINDERELLA FLUE TERMINAL CAP
NOTE!
The Cinderella Original installation Kit includes a flue terminal cap that is designed for
optimal flow and increased product efficiency. This cap consists of two parts, where the
base section can be fixed to the pipes with stainless screws or glue for easy connection
and removal for maintenance of the ventilation pipes. Use the 500 mm pipe included in
the Cinderella installation kit as the last section of the ventilation pipe. This will utilise the
connection of the flue terminal cap.
2.5.4 GAS INSTALLATION
When connecting gas to the toilet, make sure to use the appropriate gas regulator for your area. The connection
type on the appliance is ¼" NTP.
WARNING!
•
Only operate the toilet at the pressure shown on the type plate on the back of the toilet.
•
Only operate the toilet with the type of gas shown on the type plate on the back of the
toilet.
•
The toilet is suitable only for indoor installation.
SPECIFICATIONS
Gas connection appliance
2 x
Fuel consumption
Inlet gas pressure
Gas type
Orifice size
VALUE
NOTES
160–190 g
30 mBar
LPG
G ¼" LH
1 mm
Per incineration