2.6 ELECTRICAL SPECIFICATIONS AND REQUIREMENTS
The correct voltage, frequency and amperage must be supplied to the appliance from a dedicated, earthed circuit
that is protected by a properly sized circuit breaker. The proper voltage, frequency and amperage are listed in
this manual, and on the product rating plate on the back of the toilet. Please note: This toilet requires a 12 V 4 A
DC supply. If you need to operate it from a 240 V AC power point (GPO), please request the approved power
supply from your dealer.
Power requirements
Power consumption
Connection polarity
The respective negative and positive cables of the DC connection must not be joined to one another in a
camper, as this can cause electrical interference and damage to electrical components. The 12 V supply must be
connected on its own circuit direct to the battery, with a 10 A fuse at the start of the circuit. Use the 12 V wiring
guide to calculate the correct cable size according to the cable length.
Amps
4
When connecting the toilet to the mains DC power, take the following into consideration:
•
Make sure the cable has sufficient current rating for the expected load in the circuit, including a margin of
safety.
•
Make sure the cable cross-section is dimensioned for the intended cable run length, and that the cable will
not cause the voltage to drop.
•
Always check the polarity of the cables before connecting, as reverse polarity connection is not covered
under warranty.
NOTE!
•
•
2.7 REMOVING THE TRANSPORTATION SAFETY STRAP
The ash container is equipped with a safety strap that must be removed before use:
1. Remove the front cover.
2. Cut away and remove the plastic straps attaching the ash container to the steel frame.
12
INPUT
12 V DC (11–14.4 V)
HIBERNATION MODE
0.005 A
CROSS-SECTION
2 mm²
1 m
2 m
2 mm²
2 mm²
The connection cable must be laid in such a way that it does not come into contact with
sharp edges.
Changes to the internal electrical installation or the connection cable must be
performed by a professional tradesman or a similarly qualified person in order to
prevent safety hazards.
CURRENT
4 A
STANDBY MODE
0.09 A
POSITIVE
Red
12 V WIRING GUIDE
5 m
6 m
2 mm²
4 mm²
FUSE
10 A
INCINERATING MODE
1.3 A
NEGATIVE
Black
8 m
10 m
4 mm²
4 mm²