▶ Check the tool and batteries for damage before use after long periods of storage.
8
Troubleshooting
If the trouble you are experiencing is not listed in this table or you are unable to remedy the problem by
yourself, please contact Hilti Service.
8.1
The combihammer is in working order.
Trouble or fault
The battery runs down more
quickly than usual.
The battery doesn't engage
with an audible click.
The control switch can't be
pressed, i.e. the switch is
locked.
The drive spindle doesn't
rotate.
The combihammer switches
itself off automatically.
The combihammer or the
battery gets very hot.
The insert tool can't be re-
leased.
The drill bit makes no
progress.
8.2
The combihammer is not in working order.
Malfunction
No LEDs light.
1 LED blinks.
4 LEDs blink.
*2173711*
Possible cause
Battery condition is not optimal.
The retaining lugs on the battery
are dirty.
The forward / reverse switch is in
the middle position.
The permissible operating temper-
ature of the combihammer's elec-
tronics has been exceeded.
The battery is discharged.
The overload cut-out has been
activated.
Electrical fault.
The combihammer has been
overloaded (application limits
exceeded).
Chuck not pulled back fully.
The combihammer is set to run in
reverse rotation.
Possible cause
The battery is not fully inserted.
The battery is discharged.
The battery is too hot or too cold.
The battery is discharged.
The battery is too hot or too cold.
The combihammer has been over-
loaded briefly.
2173711
Action to be taken
▶ Replace the battery.
▶ Clean the retaining lugs and refit
the battery.
▶ Push the forward / reverse
switch to the right or left.
▶ Allow the combihammer to cool
down.
▶ Change the battery and charge
the empty battery.
▶ Release the control switch.
Allow the combihammer to cool
down. Press the control switch
again. Reduce the load on the
tool.
▶ Switch the combihammer off
immediately.
Remove the
battery and keep it under
observation. Allow it to cool
down. Contact Hilti service.
▶ Select a tool that is suitable for
the intended purpose.
▶ Pull the chuck back as far
as it will go and remove the
accessory tool.
▶ Move the forward / reverse
selector switch to the "Forward"
position.
Action to be taken
▶ Push the battery in until it
engages with a click.
▶ Change the battery and charge
the empty battery.
▶ Bring the battery to the recom-
mended working temperature.
▶ Change the battery and charge
the empty battery.
▶ Bring the battery to the recom-
mended working temperature.
▶ Release the control switch and
then press it again.