Beta 1498CB/30 Manual De Instrucciones página 14

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 31
END-OF-CHARGING
1. Once the battery is charged, unplug the power supply lead of the battery charger from the mains.
2. Disconnect the output lead with black clamp from the vehicle's earthing or from the negative terminal (-) of the battery.
3. Disconnect the output lead with red clamp from the positive terminal (+) of the battery.
ANALYSING THE BATTERY AND ERROR INDICATORS
The BETA battery chargers are designed to analyse the state of the battery before starting to charge it and to point out any
possible connection anomalies found between the battery charger and the battery to be charged.
Error indications
INDICATION
A few seconds after you
press the START key,
the
FAULT
LED
switches on steady and
the
acoustic
indicator
sounds.
A few seconds after
pressing the START key,
the CHARGING LED (I)
starts to blink.
The
REVERSE
(F) starts to blink and
the
acoustic
indicator
sounds.
SAFETY DEVICES
The BETA battery chargers are equipped with safety devices to guarantee utmost safety during use and operation of the
appliance.
Full protection against sparks
Protection against short-circuits
Voltage compensation
Temperature compensation
Protection against overheating
Protection against reversed polarity
High protection rating IP65 or IP41 against external agents (based on the model purchased).
14
All manuals and user guides at all-guides.com
CAUSE
-
The battery's voltage is lower than 3
Volt.
-
The battery's voltage is too high:
higher than 15 volt (for 12 Volt
batteries) or higher than 7.5 Volt (for
6 Volt batteries)
-
Short-circuit in the battery or the cell
(G)
of the battery.
You are attempting to charge a 12 Volt
battery with the battery charger set on
6 Volt.
You are attempting to charge a 6 Volt
battery with the battery charger set on
12 Volt.
The battery charger is attempting to
recover an exhausted battery.
LED
The clamps of the output leads are
not connected correctly to the battery
terminals.
SOLUTION
The battery could be defective. Contact your
nearest battery service centre.
After pointing out the defect, the battery
charger automatically switches back to "stand-
by" mode.
Unplug the power supply lead from the mains
to reset the setting. Plug back into the mains
and set again the voltage corresponding to that
of the battery.
Start charging the battery again (see section:
"How to use the battery charger").
Unplug the power supply lead from the mains
to reset the setting. Plug back into the mains
and set again the voltage corresponding to that
of the battery.
Start charging the battery again (see section:
"How to use the battery charger").
Unplug the power supply lead from the mains
to reset the setting. Plug back into the mains
and set again the voltage corresponding to that
of the battery.
Press the START key. The CHARGING LED
starts to blink again to point out that the charger
is attempting to recover an exhausted battery.
Wait a few seconds, if the FAULT LED switches
on, it means that the attempt to recover the
battery has failed and the battery needs
replacing.
Unplug the power supply lead from the mains,
position the clamps correctly and plug back into
the mains (see section: "How to use the battery
charger").

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

1498cb/801498cb/120

Tabla de contenido