Amprobe AC40C Manual De Uso página 13

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

All manuals and user guides at all-guides.com
Input Impedance: 1 MΩ
Overload Protection: 600 V rms
AC Voltage (AC40C)
Range
400 V
600 V
Input Impedance: 1 MΩ
Measuring method: Dual slope integration. Average Sensing,
rms indication. Overload Protection: 600 V rms
AC Current (AC40C/AD40B)
Range
40A
40A
400A
400A
Overload Protection: 660 A
Accuracies are specified for conductor centered in the jaw. If
the conductor is not centered, an additional error of max 1.5%
can result.
Measuring method: Dual slope integration. Average Sensing,
rms indication.
Resistance (AC40C)
Range
400 Ω
Max open circuit voltage, AC40C: -1.2 V nominal
Overload Protection, AC40C: 600 Vrms
Accuracy (40 – 450 Hz)
±(1.5 %rdg +10 dgt)
50-60Hz;(+/-3% rdg + 15dgts) 400Hz
±(1.5 %rdg +10 dgt)
50-60Hz;(+/-3% rdg + 15dgts) 400Hz
Frequency
50/60 Hz
60 – 400 Hz
50/60 Hz
60 – 400 Hz
Accuracy
±(1.0 %rdg + 5 dgt)
Accuracy
±(2.5%rdg +10dgt)
±(4.0%rdg +10dgt)
±(2.5%rdg +10dgt)
±(4.0%rdg +10dgt)
9
Resolution
0.1 V
1 V
Resolution
0.01A
0.01A
0.1A
0.1A
Resolution
0.1 Ω

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ad40b

Tabla de contenido