Before Starting The Equipment; General Information - EINHELL TC-SS 405 E Manual De Instrucciones

Ocultar thumbs Ver también para TC-SS 405 E:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 87
All manuals and user guides at all-guides.com
Keep the noise emissions and vibrations to a
minimum.
Only use appliances which are in perfect wor-
king order.
Service and clean the appliance regularly.
Adapt your working style to suit the appliance.
Do not overload the appliance.
Have the appliance serviced whenever ne-
cessary.
Switch the appliance off when it is not in use.
Caution!
Residual risks
Even if you use this electric power tool in
accordance with instructions, certain resi-
dual risks cannot be rules out. The following
hazards may arise in connection with the
equipment's construction and layout:
1. Lung damage if no suitable protective dust
mask is used.
2. Damage to hearing if no suitable ear protec-
tion is used.

5. Before starting the equipment

5.1 General information

All covers and safety devices have to be pro-
perly fitted before the machine is switched
on.
It must be possible for the blade to run freely.
When working with wood that has been
processed before, watch out for foreign bo-
dies such as nails or screws etc.
Before you actuate the On/Off switch, make
sure that the saw blade is correctly fitted and
that the machine's moving parts run smoothly.
Before you connect the machine to the power
supply, make sure the data on the rating plate
is the same as that for your mains.
5.2 Assembly
Caution! Pull out the power plug before carrying
out any maintenance and conversion work on
your fretsaw.
For greater stability, fasten the equipment in
addition to a workbench or similar (Fig. 8). Suita-
ble fastening materials such as screws etc. are
available from your dealer.
Anl_TC_SS_405_E_SPK9.indb 18
Anl_TC_SS_405_E_SPK9.indb 18
GB
5.2.1 Mounting the saw blade guard and the
sawdust blower facility (Fig. 4/5)
Fasten the retaining pin and the saw blade
guard to the arm (19) as shown in Fig. 4.
The saw blade guard can be fixed at various
heights with the clamping screw (11).
Mount the blow-off device (16) as shown in
Fig. 6.
5.2.2 Changing the blade (Fig. 1/3/6a)
Turn the clamp lever (14) counterclockwise to
release the saw blade (15).
Unscrew the left cover (4).
First take the blade out of the top blade hol-
der (13), pressing down the upper pendulum
arm as you do so.
Then take the blade out of the bottom blade
holder (8).
Pull the blade up and out through the table
insert (18).
Install the new blade in reverse order.
Use the supplied Hexagon key (24) to clamp-
fit the saw blade in the holder
Caution: Always insert the blade so that the
teeth point toward the saw table.
Turn the clamp lever (14) clockwise to clamp the
saw blade.
5.2.3 Tilting the saw table (Fig. 7)
Undo the locking screw (5).
Tilt the table (7) to the left until the indicator
(17) points to the required angle value on the
scale (6).
Important: For precision work you should
fi rst carry out a trial cut and then re-adjust
the tilt angle as required.
5.2.4 Clamp-fi tting a coping saw blade (Fig.
6b-6c)
Many commercially available coping saw blades
can also be used with this machine.
Remove the saw blade as described in 5.2.2
Pass the coping saw blade down through the
table insert (18) and into the bottom holder
(8)
Use the supplied Hexagon key (24) to clamp-
fit the saw blade in the holder
Insert the saw blade into the top holder (13)
and clamp-fit with the supplied Hexagon key
Turn the clamp lever (14) clockwise to clamp
the saw blade
- 18 -
22.02.2019 06:20:47
22.02.2019 06:20:47

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

43.090.40

Tabla de contenido