4.9 Scheduled maintenance table
MAINTENANCE OPERATION
Checking the oil level
Draining the condensation
Routine cleaning of compressor
Cleaning the intake filter
Replacing the oil
General cleaning of compressor
Check belt tension
Check/cleaning valves
4.10 Recommended oils
(suitable for room temperature ranging from +5°C and + 25°C)
SHELL Rimula D Extra 15W-40
AGIP Dicrea 100
CASTROL Aircol PD100
IP Calatia Oil ISO 100
TOTAL Dacnis P100
Room temperature below +5°C ISO 68
Room temperature above +25°C ISO 150
ELECTRICAL
POWERED
EXPLOSION
ENGINE
All manuals and user guides at all-guides.com
4.MAINTENANCE
5.TECHNICAL DATA
Power
Voltage
HP
Volt/Ph.
1.5
230/1
2
230/1
3
230/1
4
230/1
4
400/3
Power Fuel
quantity
HP
lt.
3.5
1.9
Lead free gasoline (min.77 octane)
5
3.8
Lead free gasoline (min.77 octane)
9
6
Lead free gasoline (min.88 octane)
11
7.1
Lead free gasoline (min.88 octane)
Every
Every
day
week
X
X
X
X
X
API CM-8X
BP Energol CS100
ESSO Exxc Olub H150
MOBIL Rarus 427
FUCHX Renolin 104L VG100
Absorption
cross section
A
7.5
9
12.5
17
7
Fuel type
E / 9
Every
Every
6 months
2 years
X
X
X
Cable
Sectioning
switch
mm²
A
-
-
-
-
-
-
-
-
1
20
Fuel
Engine
consumption oil q.ty
lt/h
1
1.2
2.3
2.8
ENGLISH
X
lt.
0.6
0.6
1.4
1.5