Troubleshooting - WAGNER VKM592 Manual De Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 53
Fault
Pressure drop
The pressure switch valve
leaks
air
when
compressor has been
running for more than 1
minute.
The compressor stops and
does not start.
The compressor does not
stop even though the max.
pressure allowed has
been reached. The safety
valve triggers.
The compressor does not
hold regular speed
The compressor does not
get to the set pressure and
overheats too much.
The compressor is noisy
with metallic clangs.
The compressor stops
while it is running
All manuals and user guides at all-guides.com

6.TROUBLESHOOTING

Cause
Suction filter clogging
Failure of the loadless-start
the
valve
Overload cutout tripped
(SINGLE-PHASE)
Heat relay tripped
(THREE-PHASE)
Winding burnt out.
Wrong operation or pressure
relief valve for loadless
running broken.
Belt is slipping
Compressor head gasket
broken or valve faulty.
Bearing or bush seizure.
Pressure relief valve for
loadless running faulty
Fuel has finished
Remedy
Clean the suction filter or replace if
damaged
Replace the valve
Power off through the pressure
switch, then press the restart button
If the overload cutout or the relay trip
again, contact a specialised
technician.
Contact a specialised technician.
Contact a specialised technician.
Tension up
Stop the compressor and contact a
specialised technician.
Stop the compressor and contact a
specialised technician.
Contact a specialised technician
Fill up the tank. On some models the
rubber plug covering the hole on the
protection sheet should be removed
first.
E / 10

Publicidad

Tabla de contenido
loading

Productos relacionados para WAGNER VKM592

Tabla de contenido