8.9.5
Cleaning the group shower screen,
shower screen containment ring
and filter holder
Daily
Clean the dispensing group and filter holder shower screens
with the supplied brush on a daily basis.
Thoroughly clean the inside of the coupling ring and filter
holder, as well as the edge and the wings of the filter holder,
so as to eliminate any accumulated coffee residues.
Use the special brush supplied (see the Spare Parts
Catalogue).
Weekly
Clean the shower screen and shower screen containment ring
as follows:
• Loosen the screw using a screwdriver (1).
• Remove the shower screen (2) and the shower screen con-
tainment ring (3).
• Wash the two components with
hot water.
• Reposition the shower screen
and shower screen containment
ring in their original position and
lock everything in place with the
screw.

Cleaning the steam nozzle

8.9.6
Weekly
Clean the steam nozzle as follows:
• Insert the steam wand into a jug with water and a specific
cleaner, in accordance with the manufacturer's instruc-
tions.
• Heat the solution with the steam noz-
zle.
• Let the nozzle cool down whilst keep-
ing it immersed in the solution for at
least 5 minutes, so that cleaner can rise
inside the nozzle due to the cooling ef-
fect.
• Repeat the operation 2 or 3 times until no more milk resi-
due is dispensed.
USER Manual
8.9.7
Cleaning the table
Before cleaning the table, remove the tray using the side
grips.

9. SPARE PARTS

Machine components and/or parts must only be replaced by
the Technician.
Under no circumstances are Users authorised to
replace machine components and/or parts.

10. DECOMMISSIONING

A Technician must be called out to decommission the ma-
chine as the equipment must be disconnected from the elec-
tricity and water mains, and all the internal circuits must be
emptied of water.
After being decommissioned, the machine can only be re-
commissioned by a Technician.
Under no circumstances are Users authorised to
decommission and/or recommission the machine
after long periods of inactivity.