5.2.4
Entering the filter capacity
Key
Press the "MENU" key until CAP SET is shown�
- Display: Set filter capacity.
Press and hold the "MENU" key for approx� 5 seconds�
- The active digit flashes.
Press the "MODIFY" key:
- Set the active digit�
Press the "MENU" key:
- Confirm the active digit and move to the next digit.
- The active digit flashes (repeat the procedure until the last digit).
Based on the local carbonate hardness of the tap water, use the table in Chapter 4�3 to determine the
resulting capacity of the filter cartridge.
5.2.5
Counter reading (when inserting the cartridge)
It is possible to call up the total counter reading when replacing the last 5 filter cartridges.
Key
Press the "MENU" key until the counter reading is shown�
- Display of the counter reading at which the current cartridge was inserted�
Press and hold the "MENU" key for approx� 5 seconds�
- The digit "-1" is shown = Total counter reading at the last but one
replacement of the cartridge�
Press the "MENU" key:
- The digit "-2" is shown, it is possible to continue to press until "-4"�
Output of the counter reading (total number of liters) of the last 5 cartridge replacements.
5.2.6
Alarm
Key
Press the "MENU" key until the alarm is shown�
- Display: Alarm�
Press and hold the "MENU" key for approx� 5 seconds�
- "ON" or "OFF" is shown�
Press the "MODIFY" key:
- Switch between "ON" and "OFF"�
Press the "MENU" key:
- The current setting is applied�
When switched on (beep on), an acoustic signal sounds when the remaining capacity is 10% or after a
maximum period of use of 12 months when water is drawn off.
5.2.7
Setting the unit (liters or gallons)
Key
Press the "MENU" key until the settings are shown�
- Display: Settings�
Press and hold the "MENU" key for approx� 5 seconds�
- "L" or "Gal" flashes.
Press the "MODIFY" key:
- Switch between "L" and "GAL"�
Press the "MENU" key:
- The current setting is applied�
- 11 -
Display
en
Display
Display
Display