5.10 Structure and access rights to the operating software
Sub-menu
2nd level
Cross-section / Status /
piece counter
1/2 cross-section
1/2 language
2/2 Start monitoring
2/2 Button sounds
1/1 Reference run, jog mode
forwards
Jog mode
1/1 Reference run, jog mode
forwards and backwards
1/1 Start / Magazine stop / Cover
Status I/O
status
1/1 Q1 / Q2 / Q3
Status I/O
2/2 A1 / A2 Off/On
Status I/O
2/ 2 temperature, voltage
Status I/O
Stripping / position
Cutting blade
Stripping / reference
Cutting blade
Separate / position
Cutting blade
Cut / reference
Cutting blade
Input four digit code
Users
1/3 Software
1/ 3
Reset piece
counter
1/3 Total
1/3 Service
1/3 Day
2/3 Default settings
2/3 Endurance test
2/3 Software
3/ 3, Piece counter, type
2859970000/00/02.2022
Access rights Description
Production
Operator
Display during operation, changing menu settings
Setting
Operator
Setting the conductor cross-section display
Operator
Setting the language
Operator
Start sensor must be pressed longer: Yes/no
Operator
Touch display sound: Yes/no
Service
Reference run back to the starting position
Operator
Complete crimping cycle forwards step by step
Reference run back to the starting position
Installer
Complete crimping cycle backwards step by step
Operator
Check status in case of a malfunction, forward info to service personnel.
Operator
Check status in case of a malfunction, forward info to service personnel.
Installer
Switch outputs A1 and A2 (not active) off and on
Installer
Current temperature inside the machine and current voltage
Installer
Approach the position to exchange the stripping blade
Installer
Reference run back to the starting position
Installer
Approach the position to exchange the separating blade
Installer
Reference run back to the starting position
Installer code = 1212.
Operator
Enter any code to set the operator.
Info
Operator
Installed software version
Operator
Reset daily piece counter to 0
Operator
Crimp cycle total piece counter
Operator
Crimp cycle service piece counter
Operator
Crimp cycle daily piece counter
Installer
Reset all values to the default settings
Installer
Switch the endurance test on or off
Installer
Start an operating software update
Service
Reset the total piece counter, set the type
Operating software
41