7. USER INSTRUCTIONS
7.1 DESCRIPTION of the DISPLAY
KEYS
FUNCTIONS
Control switch-on
Confirmation of value selected
time, temperature, start/end cycle SET
Selecting cycle to start
Selecting temperature cycle
Selecting time cycle
Increasing the values
Defrosting activation
Decreasing the values
LED
ON
Timed blast chilling is in progress
Timed post-blast chilling preservation is in progress
Needle probe blast chilling is in progress
For ½ sec. every 3 sec.: the test is in progress to check
the correct introduction of the needle probe
Needle probe post-blast chilling preservation is in prog-
ress
From a blast chilling cycle it has passed to the
End
preservation phase
A preservation phase is in progress
Defrosting is in progress
-d-
Draining is in progress
Alarm in progress
°C = temperature value in degrees Celsius
/
°F = temperature value in degrees Fahrenheit
Display:
- the residual time in the case of timed cycle
- the core temperature during the needle probe cycle
- the cell temperature in the case of preservation
LED
STATE
Flashing
+
+
On
Flashing
+
+
On
Flashing
+
+
+
On
FLASHING LIGHTS
A timed blast chilling cycle has been selected
The work Set-point is being modified during preser-
vation
A temperature blast chilling cycle has been
selected
The work Set-point is being modified during preser-
vation
The work Set-point is being modified during preser-
vation
MEANING
The test regarding the correct introduction of the needle
probe has had a negative result
From temperature blast chilling it has passed to timed
blast chilling
1. If the probe has not detected that the blast chilling
end temperature has been reached within the max
default times: the blast chilling phase continues
Preservation phase after needle probe blast chilling
with negative result due to maximum time being
exceeded
21 - EN