3.8
ERROR MASSAGES
Error
message
No.
1
Inverter overvoltage
2
Inverter overcurrent
3
Inverter overheating
Network
4
synchronization
error
5
Fan fault I
6
Fan fault II
Power supply
7
instability I
Power supply
8
instability II
High inverter
9
frequency
CAUTION! If the device shows any signs of thermal or mechanical damage, or shows no signs
of operation, or if any error lingers after changing the power supply, the heating inductor or the
working object, do not use the device anymore, disconnect it from the grid power supply, place
it on a fireproof surface, leave it to cool safely for 20 minutes and contact the device vendor.
BGS technic KG
Bandwirkerstr. 3
D-42929 Wermelskirchen
Error title
Error due to connection of the instrument to a power supply
network with too high a voltage greater than 276 VRMS, due to
non-standard behaviour of the working load or due to defective
HW.
Error caused by excessive load on the heating inductor, use of a
non-original heating inductor, non-standard behaviour of the
working cartridge or defective HW.
Error indicating overheating, failure to follow the recommended
duty cycle or non-standard thermal stress on the instrument.
This is an error in the HW part that is responsible for
synchronization with the network.
Instrument fault due to dust clogging, fan braking, jamming or
electrical short circuit.
Instrument error due to fan connection discontinuity or fan
inactivity
Power supply error of secondary circuits of the device -
overvoltage of secondary circuits.
Power supply error of secondary circuits of the device -
undervoltage of secondary circuits.
Error related to short circuit on the inductor or too low
inductance (use of non-original inductor).
Tel.: 02196 720480
Fax.: 02196 7204820
mail@bgs-technic.de
11