SUPPLEMENTARY INSTRUCTIONS FOR THE INSTALLER
This manual supplements the one supplied with wall-mount boilers.
The Combi unit is used to convert a heating-only wall-mount boiler into a base boiler that generates domestic hot water
thanks to a heater with a capacity of 79 litres made of AISI 316 L stainless steel.
The following technical instructions and notes are intended for installers so they may make a perfect
installation.
The instructions for igniting and using the boiler are given in the boiler manual.
The unit is sold on a wooden pallet protected by packing made of strengthened cardboard.
The packed unit must only be transported and lifted by holding it underneath the pallet.
CAUTION:
- This unit is to be combined only with a boiler.
- The bottom of the unit is secured to the wooden base with a screw.
To unscrew it, take off the cardboard packing and remove the door.
- The packing elements (plastic bags, polystyrene, etc.) must not be left within reach of children as they are potentially
hazardous.
2. FITTING THE APPLIANCE (Combi unit + wall-mount boiler)
Before installing the boiler it is necessary to fit the wall-mount boiler to the Combi unit.
• 5 Seals G 3/4" + 1 Seal G 1/2"
• Side panels
• Crosspiece for side panels + 4 self-tapping screws
• Condensation runoff pipe with clamps
• Filling hose with tap and clip..
• Delivery/storage boiler coil connection hose.
To carry out this operation, proceed as indicated in figure 1 and in the following instructions:
• Attach the filling hose and the delivery/storage boiler coil connection hose to the relative connectors;
• Take the wall-mount boiler out of its packing and place it over the unit with the front parts aligned;
• Secure at the front the boiler to the Combi unit with the side-panel brackets;
• Screw the pipes on the Combi onto the boiler's plumbing connections, inserting the seals supplied in the outfit (after
removing the G 3/4" plug on the coil delivery connection);
• Attach the G 1/2" tap to the boiler domestic cold water connector and attach the hose to the tap;
• Connect the condensate drain hose (supplied) to the boiler siphon (secured with clamps);
• Couple the side panels onto the sides of the boiler.
Insert the side panels and the crosspiece only after finishing installing the appliance.