Connect Vent System; Electrical Connection - Dacor DHDU990W/DA Serie Instrucciones Para Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation

Connect vent system

1.
Fit vent system over the transition adapter
2. Fit the transition adapter over the exhaust outlet.
E
B

Electrical connection

WARNING
ELECTRICAL SHOCK HAZARD.
WARNING
DISCONNECT POWER BEFORE SERVICING.
REPLACE ALL PARTS AND PANELS BEFORE OPERATING.
FAILURE TO DO SO CAN RESULT IN DEATH OR
ELECTRICAL SHOCK.
1.
Disconnect power.
2. Remove terminal box cover.
3. Remove the knockout in the terminal box cover and
install a UL listed or CSA approved ¹⁄₂" strain relief.
A
A. Knockout
B. Terminal box cover
A
A. 10" round transition
D
B. Transition adapter
C. Hood assembly
D. 4 - 3.5 x 9.5 mm screws
C
E. 4 - 4.2 x 8 mm screws
B
3. Measure from the wall or roof outlet to the to the top
ceiling. Cut the ductwork at the measured dimension
and place it over the transition.
Roof Outlet
Wall
Outlet
4. Seal connection with clamps.
5.
Use caulk to seal all openings.
4. Run home power supply cable through strain relief,
into terminal box.
A
B
C
A. Home power supply cable
B. Black wires
C. UL listed wire connectors
D. White wires
E. Green (or bare) and yellow-green ground wires
F. Power board ground wires
G. Fan ground wires
5. Use UL listed wire connectors and connect black
wires (B) together.
6. Use UL listed wire connectors and connect white
wires (D) together.
Dimension to
Measure
12.5
36.6
F
G
E
D
ENGLISH
15

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dhdu790ls/da serie

Tabla de contenido