LOW PROFILE MOUNT INSTALLATION
Building Structure
While supporting the fan, loop safety cable around building structure and secure with
shackle (Fig. 6c). Acceptable building structures include a wooden beam or a metal
mounting brace secured between two beams. In some cases, it may be necessary to
install additional structural material to provide attachment points.
Fig. 6c
7. Wire fan
Disconnect power to fan location before wiring fan.
Do not connect fan to a damaged power source. Do not attempt to resolve
electrical failures on your own. Consult a qualifi ed electrician if uncertain of the
electrical installation of this fan.
Allow fan to hang from safety cable. Wire fan as shown on the following page using the
wire connectors (Fig. 7).
Carefully tuck wiring into outlet box or building structure. Ensure wire connectors are
turned upward and that wires are spread apart with grounded conductors on one side
of the outlet box/mounting structure and ungrounded conductors on the other side.
Wire Connector Operation
1
30
Safety Cable
WARNING
2
Shackle