POOL RX LT

GENERAL FEATURES

• Power Supply 220-240 Vac
• Display 4 digits with 7 segments
• Bnc connection for probe Redox/ORP
• Switch 3 position Priming, ON, Stand by
• Dry contact relay, please look at label on product
• Measure Range Redox/ORP: 400÷999 mV (resolution: 10 mV)
• Dosage method ON-OFF ( Set Point adjustable)
• Calibration method Redox/ORP 1 Point (465 mV)
SWITCH POSITION:
1) Priming position "the pump running" (Switch position MOM)
2) Normal position "the instrument measure Redox and dosing. (Switch position ON)
CAL
Keep pressed
key for 5 seconds to run calibration menu:
Redox probe:
CAL
the pump displays C465 press
key and wait 60 seconds Displays quality probe ex: C100
Press the button
to stop the calibration.
SET
Keep pressed
key until flashing Setpoint value and press again to increase the value.
SET
After 3 seconds from releasing the key
the value will be saved and the pump will display mem.
SET
The range of values is included between 400 and +990 mV with an increase of 10 mV.
When the real measure is less than 400 mV and higher than 999 mV the measure displayed flashes.
3) Stand by position "The pump is stop" (Switch position OFF)
CAL
Keep Press
key for 3 seconds to run Setup menu: Redox setup menu:
Adjust dosage method High ("Hi") or Low ("Lo").
5