Installation Guide
H/U952T Terminal Transmitter
IMPORTANT: Overheating during soldering may damage insulation between inner
6
Check with ohmmeter for short circuit between connector body and inner
conductor.
Note: If the cable is connected to a dc-grounded antenna, disconnect it before
making this check.
7
Insert washer and screw (3).
When connecting the antenna cable to MPT-50 Power Divider and Slave transmitters, the
connector PL259 (UHF) is used.
Assemble PL259 Coax Connector as follows:
1
2
Figure 18. Assembly of PL259 coax connector.
1
Cut and strip cable as shown in figure at (1).
2
Slide coupling ring onto cable and screw connector body onto cable (2).
3
Solder braided shield to body through the two solder holes.
IMPORTANT: Overheating during soldering may damage insulation between inner
4
Cut inner conductor diagonally as shown and solder to connector.
5
Screw coupling ring onto body.
6
Check with ohmmeter for short circuit between connector body and inner
conductor.
Note: If the cable is connected to a dc-grounded antenna, disconnect it before
making this check.
2002-11-13/ Rev. A
conductor and shield resulting in negative effects on cable.
screw coupling
ring onto body
Coupling
ring
Connector body
conductor and shield resulting in negative effects on cable.
8
20
1
(dimensions in mm)
cut before
soldering
solder
Handook page
43/128
TD 92022GB
14