Installation Guide
Alarm Module T941AM8
5. Addressing
Select the proper address by setting address selector
switch SW01 (see the document System Installation,
under "Addressing"). The address must not be 00
nor the same as any other 900 unit address.
6. Selection of A or B Bus
A bus is normally used (always used in CTS 900).
To use B bus: remove the 0 ohm resistors R01, R02
from the PC board and solder together jumper points
S01 and S02. (See drawing above.)
7. Wiring Runs
The plastic partition (shaded in the drawing) is scored
to facilitate breaking at convenient intervals.
1995 08 31
OFF
ON
SW01
R01
R02
S01
S02
1
1
1
2
3
4
5
6
2
1. Use pliers to break off a suitable section.
2. Run the wiring out through the partition.
Wiring can be run three ways from the alarm
module:
• Remove the rectangular pieces and run the
cabling out through the side (1).
1
1
8
• Break off sections at short side of case and run
the cabling downwards (2).
• Run the cabling through the round holes at the
bottom of the case (3)
Secure the wiring with cable straps.
8. Connecting Supply Voltage and Buses
1. Supply voltage is connected to screw 1 and 2 of
screw connector J03. (See the document "System
Installation", under "Supply Voltage").
2. Connect modular bus cabling to J01 and J02
(1 in drawing at below left),
and / or
A or B bus to J03 screw 5 and 6
(dwg below and 2 in drawing at left).
Use only A bus in CTS 900 !
NOTE: The data lines are polarised. Use only
3
3
2
2
twisted-pairs for two-wire connections!
Supply voltage in
Supply voltage out
A or B bus
TD 90858GB