Check List; Faultfinding - Nilfisk Gerni N/G-411A Instrucciones De Manejo

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 59
ACTION
WHAT/WHO
Instruct
New operator
Check
High pressure hose
Check
Pressure gauge
Check
Detergent suction
Clean
Water filter
Clean
Fine sand
filter
Clean
Turbo Laser
filter
Check
Oil level -
pump
Check
Oil -
electric motor
Check
Gaskets
Perform
Oil change - pump
Symptoms
High pressure cleaner
does not start.
32
All manuals and user guides at all-guides.com

CHECK LIST

WHEN/HOW OFTEN
Before operator uses
high pressure cleaner
During daily use
During daily use
Daily - by means of
detergent
Weekly/as needed
As needed
As needed
During daily use
Once a year
Every other month
After 300 hours
operation - at least
once a year

FAULTFINDING

Cause
Switch not
activated.
Lack of water.
High pressure cleaner not
connected to the power.
Fuse burnt out.
HOW
Let operator read
instruction guide
Leaks? - call
service engineer
Too high/too low? -
call service engineer
Lack of suction/leaks? -
call service engineer
See maintenance
See maintenance
See maintenance
See maintenance
Lack of oil? - call
service engineer
Leaks? - call
service engineer
See maintenance
Corrective action
Turn switchto pos. "AUT" or "1".
Open tap completely.
Insert the plug, switch on
the main power supply.
Change fuse. If fuse burns out again,
contact service department.