6
pRepaRINg tHe place
oF INStallatIoN
6.1
general considerations
The following sections contain some guidelines
to be followed to obtain the maximum efficiency
of the product purchased and to ensure safe
operation. The following indications are however
subject to compliance with any possible nation-
al, regional and municipal laws and regulations
in force in the country where the appliance is
installed.
In Italy, installation must be performed by quali-
fied personnel in compliance with the UNI 10683
standard.
6.2 Safety precautions
The operations for assembly and disassembly of
the appliance are reserved for specialist techni-
cians only.
It is recommended to be sure of their qualifica-
tions and their actual capacity.
For Italy, these technicians must be in
possession of the letter "C" qualifica-
tion issued by the chamber of com-
merce based on the Ministerial Decree.
37/08.
48
6.3 place of installation
For the minimum distances that must be re-
spected when positioning the appliance with
respect to flammable materials and objects, refer
to the instructions in Fig. 8.
Y2
X1
Product images are for illustrative purposes only
model
x1
ecopalex gtm
70 - 80
800 300 400 400 1000 mm
90
800 300 500 500 1000 mm
Floors made of flammable material such as wood,
parquet, linoleum, laminate or floors covered
with carpets must be protected by a fireproof
base under the appliance that also protects the
front during cleaning from any falling burning
residues.
The manufacturer declines all responsibility for
any variations in the characteristics of the mate-
rial constituting the floor under the protection.
Set up an accessible technical space
for any maintenance work.
Remember to respect the minimum distance
from flammable materials (x), shown on the
identification plate of the pipes used to make the
chimney.
Prepare the arrival of the electric line near the
appliance for the connection of the power supply
cable (if present).
Z
X2
Y1
Fig. 8
x2
Y1
Y2
Z
004778990 - 11/02/2022