clearing Jams:
Should a fastener jam occur, disconnect air supply.
2
1
3

Features

➀ Release the feeder shoe and slide it forward.
➁ Remove fasteners from the tool.
③ Loosen screws using hex wrench at the rear of the tool by hand. Pull magazine back.
Clear jammed fastener from guide body.
Slide magazine back into position and attach screws.
Connect air supply and replace fasteners.
Pull feeder shoe back.
To adjust the depth the fastener is driven:
First disconnect the air supply.
Using your thumb or index finger, rotate wheel to adjust the Depth Control workpiece
contact (safety element) to achieve desired depth.
The tool can be converted for non-toenail (flat surface) applications by adding the no-mar
pad.
Use no-mar pad to prevent damage to work surface.
TOOl use