Lubrication Oil Adjustment; Overpressure And Vacuum Adjustment Valves - battioni Pagani BALLAST 3500 Manual De Instrucciones De Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 132

6.6 LUBRICATION OIL ADJUSTMENT

To adjust the dripping of oil in the Rotary blades vacuum pump with forced lubrication, turn the regulator ring nut "A" (see Figure
8) after loosening ring nut "B".
Tighten ring nut "B" again when adjustment has been completed.
The adjustment of oil delivery, in automatic lubrication, is carried out at our factory during final testing of the Rotary blades vacuum
pump.
If for a particular reason a different setting is required, proceed as follows: remove the pin cover (see Figure 9), loosen the nut "C"
and then act on the "A" adjustment pin.
By rotating clockwise lower oil delivery is obtained (-), and by rotating anticlockwise higher oil delivery is obtained (+). When
adjustment has been completed tighten lock nut "C" and screw cover.
-
B
Figure 8
7 – OVERPRESSURE AND VACUUM ADJUSTMENT VALVES
The following diagram describes the standard valves (O), those available upon request (X) and those not available (-) for each model
of rotary blades vacuum pump.
BALLAST 3500-4500-6000-7500
BALLAST 9000-11000-13500
BALLAST 16000
Table 4
A
+
ADJUSTMENT VALVE
O = Standard
X = Upon request - = Not available
instruction manual BALLAST series
Figure 9
VACUUM
OVERPRESSURE
VALVE 1" 1/2
1" 1/2
-
X
X
user and maintenance
OVERPRESSURE
VALVE 2"
X
-
-
X
-
-
p. 49

Publicidad

Tabla de contenido
loading

Tabla de contenido