Red_1 = 0 Red_2 = 210
Green_1 = 79 Green_2 = 50
112-119
Blue_1 = 0 Blue_2 = 50
Amber = 220
Red_1 = 63 Red_2 = 145
Green_1 = 75 Green_2 = 166
120-127
Blue_1 = 0 Blue_2 = 100
Amber = 44
8. TROUBLESHOOTING
This troubleshooting guide is meant to help solve
simple problems. If a problem occurs, carry out the
steps below in sequence until a solution is found.
Once the unit operates properly, do not carry out
following steps. If the problem persists, refer servic-
ing to a qualified technician.
Power Connected but No Fog
Is Emitted
1. Check the power supply. Plug the unit into
grounded electric power supply socket with
proper voltage.
2. Check your controller if in correct connection,
test the battery if power enough for wireless
controller.
3. Check your DMX address setting.
4. Disconnect fog machine from electric power
supply. Replace fuse with one of the same type.
Other Abnormal Situations that Could Make
Heater & Pump Stop Working
Flashing and showing "Erro" means heater is
too hot or thermos sensor is cut.
Random_1
240-247
Random_2
248-255