Alarm Code
00500E
3G module is not ready (module itself or SIM)
00500F
WiFi module is not ready
006001
3G connection is disconnected from APN
006002
3G connection is disconnected from internet
006003
3G connection is disconnected from backend office
006008
Ethernet connection is disconnected from internet
006009
Ethernet connection is disconnected from backend office
007001
Hardware component in power rectifier is broken
007002
Input voltage of power rectifier is higher than workable range
007003
Input voltage of power rectifier is lower than workable range
007004
Output voltage is higher than workable range of power rectifier
007006
The temperature of air inlet in power rectifier is higher than workable range (> 60°C)
007008
The temperature of PFC is higher than workable range
007009
The temperature of PFC is lower than workable range
00700A
The temperature of DCDC is higher than workable range
00700B
The temperature of DCDC is lower than workable range
00700C
The fan inside power rectifier is broken
00700D
Output oring diod is broken
00700E
Isolation test is failed
008003
5 volt for system controller is higher than workable range
008004
5 volt for other system modules is higher than workable range
008005
5 volt for CAN bus is higher than workable range
008006
12 volt for other system modules is higher than workable range
008007
12 volt for EV communication is higher than workable range
008008
24 volt for relay control is higher than workable range
008009
5 volt for system controller is lower than workable range
00800A
5 volt for other system modules is lower than workable range
00800B
5 volt for CAN bus is lower than workable range
00800C
12 volt for other system modules is lower than workable range
00800D
12 volt for EV communication is lower than workable range
00800E
24 volt for relay control is lower than workable range
008010
The output current of 5 volt for system controller is higher than workable range
008011
The output current of 5 volt for other system modules is higher than workable range
008012
The output current of 5 volt for CAN bus is higher than workable range
008013
The output current of 12 volt for other system modules is higher than workable range
008014
The output current of 12 volt for EV communication is higher than workable range
008015
The output current of 24 volt for relay control is higher than workable range
Installation and Operation Manual
Description
24
System Code