Mounting the duct cover bracket
1 Determine and mark the centerline on the wall where the canopy
hood will be installed. Disconnect power.
2 Mark a reference line on the wall.
3 Tape template in place, aligning the template centerline and
bottom of template with hood bottom line and with the centerline
marked on the wall.
A.
Centerline
B.
Fastener locations
C.
Mounting height reference (hood bottom line)
4 Mark centers of the fastener locations through the template to the
wall.
IMPORTANT: All screws must be installed into wood.
If there is no wood to screw into, additional wall framing
supports may be required.
5 Remove the template.
6 Drill
" (4.8 mm) pilot holes at all locations where screws are
3
16
being installed into wood.
7 Install the 2 - 5 x 45 mm mounting screws. Leave a
mm) gap between the wall and the back of the screw head to slide
range hood into place.
"
1
4
(6.4 mm)
Vent cover bracket installation
1 Attach vent cover bracket to wall flush to the ceiling using
2 - 5 x 45 mm screws.
C
Complete preparation
1 Determine and make all necessary cuts in the wall for the
vent system. Install the vent system before installing the
hood. See "Venting Requirements" section.
2 Determine the required height for the home power supply
cable and drill a 1¼" (3.2 cm) hole at this location.
3 Run the home power supply cable according to the
National Electrical Code or CSA Standards and local codes and
ordinances. There must be enough ½" conduit and wires from the
fused disconnect (or circuit breaker) box to make the connection in
the hood's electrical terminal box.
NOTE: Do not reconnect power until installation is complete.
4 Use caulk to seal all openings.
A
C
B
"
(6.4
1
4
A
A. Ceiling
B. Wall
C. Centerline
B

Install range hood

1 Using 2 or more people, hang range hood on 2 mounting screws
through the mounting slots on back of hood.
B
C
D
A.
Mounting screws
B.
Mounting slots
2
Mark with a pencil the lower mounting holes location.
3
Uninstall the hood assembly, and drill
holes at marked locations.
4
Hang the range hood again on 2 upper mounting screws.
5
Level the range hood and tighten upper mounting screws.
6
Install 2 - 5 x 45 mm lower mounting screws and tighten.
Connect Vent System
1 Install transition on top of hood (if removed for shipping) with 2 -
3.5 x 9.5 mm sheet metal screws.
A
B
3 Fit vent system over the exhaust outlet.
4 Measure from the bottom of the air deflector to the bottom of the
hood outlet. Cut the ductwork at the measured dimension.
Roof outlet
Wall
outlet
5 Seal connection with clamps.
6 Check that back draft dampers work properly.
A
C.
Washers
D.
Lower mounting screws
" (4.8 mm) pilot
3
16
A.
Vent transition
B.
3.5 x 9.5 mm
screw
Dimension
to measure
7