Prolonged Periods Of No Use; Faults, Alarms And Breakdowns - Fagor M-G910 Instrucciones De Instalación, Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 15
It is advisable to regularly clean the inner part of the tub with soapy water that is left to boil
for a few minutes. and then rinse it with plenty of water. Then rinse it with plenty of water
and dry.
After use, all the models require regular greasing of the drainage tap with "KLÜBER
NONTROP PLB DR" or similar grease to prevent it from seizing up and to prevent possible
leaks.
A screw is located on the lower part of the pot of the Bain Marie models to empty the
chamber completely.
If the power cable is damaged, it must be replaced by the manufacturer, after-sales service or
authorised technical personnel in order to prevent risks.
5.3.3

Prolonged periods of no use

If the machine is kept out of service for a long period of time (holidays, temporary closure, ...),
please observe the following:
Close the gas supply.
Clean the machine and the adjacent areas thoroughly.
Spray a thin layer of edible oil over the stainless steel surfaces.
Switch off the mains power supply.

6. FAULTS, ALARMS AND BREAKDOWNS

The steps to be followed in the event of a fault or operating error are described below. The possible causes
and possible solutions are listed in the following table. In the event of doubt, or if you are unable to resolve
the problem, please contact the technical service.
Do not handle electrical components, as there is a risk of death as the components are
live.
Problem
Smell of gas
Ignition pilot does not light.
Ignition pilot goes out.
Flame is yellow.
Cooking pot does not heat up
(*) in Bain Marie pots
Cause
Occasional gas leak caused by
flame going out.
Spark generation does not work.
Air in pipes due to long period of
inactivity.
Thermocouple not heated enough.
Dirty burner
Broken valve
Energy control broken
Insufficient pressure in the chamber
(*)
Pressure switch broken (*)
TLimiting thermostat trips (*)
Insufficient gas pressure.
Solution
Close the gas supply and ventilate
the premises.
Manually switch on the cooking pot.
Contact your Technical Assistance
Service.
Repeat ignition process.
Repeat ignition process.
Contact your Technical Assistance
Service.
Contact your Technical Assistance
Service.
Contact your Technical Assistance
Service.
Bleed chamber with the pressure
valve
Contact your Technical Assistance
Service.
Contact your Technical Assistance
Service.
Contact your Technical Assistance
Service.
35

Publicidad

Tabla de contenido
loading

Tabla de contenido