C3:
ADAPTING MICROWAVE BLOWER FOR RECIRCULATION
1) Remove and save screw that holds blower motor to microwave, lift up the blower plate.
2) Carefully pull out the blower unit. The wires will extend far enough to allow you to adjust the blower unit.
3) Rotate blower unit 90º
4) Place the blower unit back into the opening.
5) Replace the blower plate in the same position.
B lower Motor
Back of
Microwave
Blower Plate screw
Blower motor screw
23
BEFORE : Fan Blade
Openings Facing UP
4. Rotate blower unit 90°.
Before
Rota�on
Back of
Microwave
A�er
Fan Blade
Openings Facing Front
CAUTION:
Do not pull or stretch the blower unit wiring.
Make sure the wires are not pinched.
NOTE:
The blower unit exhaust openings should match
exhaust openings on rear of microwave oven.
A�er
Rota�on
Back of
Microwave
Back of
Microwave