TECHNICAL MANUAL
LARGE DISPLAYS DN109/NB - DN119/NB - DN189/NB - DN129/NB
CHAPTER 22
Global Settings
Various parameters and options are modified on the global settings window. Such
modifications will also affect the configurable parameters of the web server and subsequent
configuration windows.
29. Selects the data port that will be used for communication.
30. Selects language used. Currently only English version is available.
31. Configures the precision of the values to be shown on the display. "AUTO" will set
dynamically the number of decimal digits for the value on display according to the digits
available on the equipment. If "USER DEFINED" is selected, a field appears to enter the
desired decimal digits.
32. Decimal digits used for the ON display value.
Below is a table of examples, in this case a 4-character display is considered.
VALUE TO DISPLAY
1.23
1.23
1.234
1.234
1.235
1.235
1.23
1.2345
1.2345
INITIALIZATION
Fig. 95: Global Settings Window.
PRECISION
USER DEFINED
AUTO
USER DEFINED
AUTO
USER DEFINED
AUTO
USER DEFINED
USER DEFINED
AUTO
Table 55: Example Table
DECIMALS
DISPLAYED VALUE
2
-
2
-
2
-
3
4
-
22-5
1.23
1.23
1.23
1.234
1.24
1.235
1.230
1.235
1.235