33. Selecting "FULL DIGIT" left digit is used only to show negative sign "-".
Selecting "HALF DIGIT" left digit takes the value "-" or "-1", so the capacity to display
negative numbers is increased.
Example: 5-digit display, minimum value in "FULL DIGIT" is -9999, while in "HALF DIGIT"
is -19999.
Fig. 96: "FULL DIGIT" and "HALF DIGIT" real example.
34. Manually set the date and time of the viewer. Clicking on the default parameter will show
the date and time of the system (PC).
35. SNTP Address/Domain that will be used to obtain the time accurately. By default, the
public SNTP server pool.ntp.org is set. It can be configured with an internal company
SNTP server or another public access server.
36. Time at which the display will turn on.
37. Time at which the display will turn off. To deactivate the automatic on/off you have to set
both (on and off) at the same time.
38. Enable daylight saving time. The time change will be done automatically if you select
"ON".
39. Allows to select the desired methods to sync the clock:
NONE: No sync.
ETH_SNTP: Uses the server set to 7.
WIFI_SNTP: The same but using WIFI. Note: Will not work in mode "ACCES
POINT").
40. Set the display time zone.
41. Sets the light intensity level of the display.
42. Clicking "UPDATE" sends the new settings to the display.