A3 TROUBLESHOOTING

Fault
Significant drop in pressure
downstream of the filter.
Leakage from the drain valve.
Pressure increase downstream
of the reducer in the presence of
a boiler
The reducer does not maintain
the calibration value
Water leaking from the pressure
reducer cap
Poor water flow to utilities

A4 DISPOSAL

Collect separately from other waste. Inquire through the municipal authority for the location of
ecological platforms suitable for receiving the product for disposal and its recycling. For clarification,
contact the producer or the Waste Management Service of your local Municipality.
BRAVOFIL PLUS – ENGLISH
Cause
Dirty filter element.
Shut-off valves not completely
open.
Sealing O-ring of the tap broken or
worn.
Drain valve not completely closed
due to a foreign body stuck in the
seat.
Out-of-phase filter.
Overheating of the water with
consequent increase in volume
Impurities present in the sealing
seats of the shutter cartridge.
Failure of the membrane on the
shutter cartridge inserted in the
valve
Partially clogged cartridge.
EN-PAG.8
Solution
Backwash.
Fully open the shut-off valves.
Replace the O-ring. Contact the
authorized Technical Assistance
Center.
Contact the authorized Technical
Assistance Center.
Contact the authorized Technical
Assistance Center.
Install an expansion tank between
the filter with reducer and the
boiler in order to absorb the
expansion.
Contact the authorized Technical
Assistance Center.
Contact the authorized Technical
Assistance Center.
Clean the filter cartridge and the
filter bowl.