3. INSTALLATION METHOD
5. Fasten the back plate of the wire controller
For exposed mounting, fasten the back plate on the wall with the 3 screws
(M4×20) and plugs. (Fig.3-5)
Screws (M4×20)
For flush-mounting, fasten the back plate on the switch box with 2 screws
(M4×25) and fasten it on the wall with 1 screw (M4×20). (Fig.3-6)
Screw (M4×20)
Screws (M4×25)
NOTICE
Put on a flat surface. Be careful not to distort the back plate of the
wire controller by overtightening the mounting screws.
Back plate
Switch box
Back plate
Fig 3-6