The display reads according to the figure below for two seconds.
4.
FULL TEST
NOTE! IF THE CYLINDER PRESSURE IS BELOW THE MINIMUM LEVEL ACCORDING TO THE SETTINGS THERE IS A WARNING
INDICATION. THE TEST CAN BE CANCELED AT ANY TIME BY PRESSING THE RED BUTTON. THE TEST WILL IN THIS CASE
SWITCH TO SHORT TEST.
Check the yellow and red LEDs (section 7, Fig. 7-A) on the display and the yellow
5.
and red BAC-light. If applicable check green, yellow and red LEDs on the HUD.
CHECK
LEDs
Close the cylinder valve and press the backlight button. Make sure to completely
6.
close the cylinder valve before pressing the backlight button.
CLOSE CYL
PRESS BLACK
The apparatus performs a leakage test.
7.
LEAKAGE
TEST
For Tally key activated apparatus the display will read according to the figure
8.
below. If the tally is not inserted from the start the display will first read "INSERT
TALLY" and then "REMOVE TALLY" when the tally has been inserted.
REMOVE
TALLY
14