TURN-BACK SIGNAL (OPTIONAL)
It can be set as a static value between 75 and 175 bar or as a dynamic value based on
the initial cylinder pressure.
At this level the display backlight turns red and is automatically lit for 10 seconds.
If the cylinder pressure increases above the set level, the turn-back signal is re-set.
If fitted and function activated, the HUD flashes (the active pressure indication LEDs)
for 10 seconds.
NOTE: WHEN DEPRESSURIZING THE UNIT RAPIDLY AFTER USE, THE APPARATUS SOMETIMES SHUTS DOWN WITHOUT ANY
LOW AIR WARNING OR TURN BACK SIGNAL.
REDUCED VOLUME (OPTIONAL)
To reduce volume when for example working in gas tight suits, pressurize the
apparatus and press the panic button when the display reads as shown below.
REDUCED SPL
PRESS RED
Press backlight button when the display reads as shown below.
REDUCED SPL
PRESS BLACK
9

AUTOMATIC DISTRESS SIGNAL UNIT(ADSU)- (OPTIONAL)

ACTIVATION/DEACTIVATION AND ALARM RE-SET
VERSION WITH TALLY KEY (ADSU)
Remove the Tally by pulling it straight out from the display unit to activate the ADSU.
Once in alarm mode the ADSU can only be re-set by inserting the Tally.
VERSION WITHOUT TALLY KEY (PASS) – PRESSURE STARTED
The ADSU is activated when the unit is pressurised.
To re-set the alarm first, press and hold the backlight button and then press the panic
button. To turn it off, de-pressurize the unit and then first press and hold the backlight
button and then press the panic button.
DURING USE
The yellow LED on the Digital Display starts to flash and the BAC beeps when the
ADSU is in sensing mode. When there is a lack of motion for 30 seconds the ADSU will
go into pre-alarm. This is indicated by an escalating audible signal from the BAC and
alternate flashing of the yellow and red LEDs on the Digital Display and the main LED
of the BAC.