GUÍA PARA SOLUCIONES DE PROBLEMAS
1. No power
(1) Symptom
1) Minute discharge does not occur at module.
2) Front LED does not activate.
(2) Process check
Is the power cord
plugged in?
Are the Line Filter and
PSU connected?
Is the correct fuse
for the PSU in place?
Plasma(F101)
Is the PSU and
15pin cable connected to
the VSC board?
Next remove all cables connected to the PSU and
switch the AV voltage to manual.
If the ST-by 5V does not operate, replace the PSU.
Copyright©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
No
Yes
No
Yes
No
Yes
No
Yes
Plug in the power cord
Connect the cable.
Replace the fuse.
Connect the 15pin cable.
- 13 -
LGE Internal Use Only
Free Datasheet http://www.datasheet4u.com/